Features

  • E.O.L. (End of Life) as of 1/30/19
  • Replaced by SS-2U50ES
  • Dimension : 240 X 100 X 70 mm
  • Application : For Industry Use
  • ATX 12V / EPS 12V
  • Watt : 500
  • PFC : Active
  • 80 PLUS
  • High efficiency
  • Low Ripple & Noise
  • 100% burn-in under high ambient temperature(50˚C)
  • 100% Hi-pot tested
  • Complies with EN61000-3-2
  • AC input full range

2U Power Supply 500W TC-2U50P80 Product Description

The 2U Power Supply 500W TC-2U50P80 is the perfect upgrade or replacement for powering an AMD or Intel based server. Ideal for 2U or 3U server cases, this 2U power supply provides your system with a 80 Plus certified power solution, as well as protection against over load, over voltage and over current situations – the perfect solution for delivering stable power to the most demanding devices. This 500W power supply also comes with a built-in, ball-bearing fan that helps provide superior air flow- ensuring optimum operating temperatures for long-lasting performance.

80-plus

 

 

 

 

AC Input

  • Input voltage: 90 to 264 VAC
  • Input frequency: 47 to 63 Hz

Protections

  • Over voltage protection: +3.3V: 3.5V – 4.8V; +5V: 5.5V – 6.82V; +12V: 13.4V – 15.6V
  • Short circuit protection: It is defined to be a short circuit load of less than 0.1 ohm

General Specifications

  • Hold-up time: >17ms
  • Efficiency: >80% at full load.
  • Voltage: 1500VAC from input to output
  • MTBF: 100,000 hours

Environmental Specifications

  • Operating temperature: 0˚C to +50˚C
  • Storage temperature: -20˚C to +80˚C
  • Relative humidity: 95% non-condensing

DC Output

OUTPUT VOLTAGE OUTPUT CURRENT REGULATION OUTPUT
MIN ( A ) MIN ( A ) LOAD LINE RIPPLE & NOISE
MAX. [P-P]
+5V 0.5 20 ±5% ±1% 50mV
+12V1 1 15 ±5% ±1% 120mV
+12V2 1 15 ±5% ±1% 120mV
+12V3 1 15 ±5% ±1% 120mV
-12V 0 0.5 ±10% ±1% 120mV
+3.3V 0.5 24 ±5% ±1% 50mV
+5VSB 0 2.5 ±5% ±1% 50mV

 

(1) The +3.3V and +5V total output shall not exceed 150 watts.
(2) total output for this subject power supply is 500 watts.
(3) Maxmum continuous load combined 12V should not exceed 35A.
(4) Ripply and noise measurements shall be made under all specified load conditions through a single pole low pass filter with 20MHz cutoff frequency. Outputs shall bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.
(5) -5V is option.